Packaging Details
- Unit Type: piece
- Package Weight: 0.8kg (1.76lb.)
- Package Size: 20cm x 15cm x 10cm (7.87in x 5.91in x 3.94in)
le="text-align: center;">
SUMMIT-708 O2 CO CO2 automotive exhaust gas analyzer
"Feature
Flue gas analyzer / combustion efficiency analyzer SUMMIT708 triple gas combustion efficiency analyzer addition to measuring O2/CO/CO2, the combustion efficiency analysis can be done, and the combination of differential thermometer, with printer stored data. SUMMIT708 boot a series of sensors to detect, to ensure working properly, SUMMIT708 must be switched on in a clean air environment, if the boot sensor is not working properly or not properly reset, the display will show an error message. SUMMIT708 can store data 50.
Flue gas analyzer / combustion efficiency analyzer SUMMIT708 type of fuel: natural gas, liquefied petroleum gas, light oil, heavy oil
Specifications
Temperature Measurement
Range: -40 to 1472 F, or -40 to 800C
Resolution: 1 ° F or ° C
Accuracy (K-type): 0.3%, ± 2 F or ± 1 C
Gross / Net Efficiency Combustion efficiency
Range: 0 to 100%
Resolution: 0.1%
Oxygen (O2) measurement
Range: 0 to 25%
Resolution: 0.1%
Accuracy: ± 0.3%
Carbon Monoxide (CO) measurements
Range: 0 to 10,000 ppm
Resolution: 1 ppm
Accuracy: ± 5 ppm or 5%, whichever is greater
Carbon Dioxide (CO2) measurement
Range: 0 to 25%
Resolution: 0.1%
Accuracy: Calculated
CO/CO2 Ratio
Range: 0 to 0.999
Resolution: 0.001
Accuracy: Calculated
General
Operating temperature range: 14 to 122 F (-10 to 50 ‘C)
Battery: 3 Each ""AA"" alkaline
Fuel: natural gas, liquefied petroleum gas, light oil, heavy oil
Display: LCD with backlight
Data storage: 50 sets of readings
Time and date: 24 hours real-time clock
Dimensions: 200mm x 90mm x 60mm
Weight: 500g
Shutdown: Failsafe
Standard: BS7927 (and the draft BS7967)
"
-->