aHR0cDovL2ZyZWVzaGlwLmNvLmty
- ºê·£µå À̸§: AUTOOL
- ¿ø»êÁö: Áß±¹
- Testing and maintenance: Refrigeration equipment: air conditioners,fridge and cold storage
- Built-in refrigerant database: 93 kinds of refrigerant NIST
- Function 1: Double pressure test
- Dual temperature test: Celsius / Fahrenheit
- Function 3: Multi-unit pressure conversion
- Function 4: Multi-mode function
- Function 5: Calculate the subcooling superheat
- Function 6: Tests percentage of vacuum measurement
- Function 7: Pressure leak measurement
- Function 8: Leak time speed record
- Pressure test: gauge pressure
- Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
- Pressure test range: 0 Kpa-6000 Kpa
- Pressure test resolution: 1 Kpa
- Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
- Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar)
- Vacuum test: relative vacuum
- Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
- Vacuum test range: -101 Kpa-0 Kpa
- Vacuum test resolution: 1 Kpa
- Temperature test unit: ¡ÆC (Celsius), ¡ÆF (Fahrenheit)
- Temperature test range: -40¡ÆC-150¡ÆC (-40¡ÆF-302¡ÆF)
³Ãµ¿ µðÁöÅÐ ¸Å´ÏÆúµå °ÔÀÌÁö ¹ÌÅÍ HVAC Áø°ø ¾Ð·Â ¿Âµµ Å×½ºÅÍ ´©Ãâ Å×½ºÆ®
Áö´ÉÇü ÀüÀÚ ³Ã¸Å ±×·ì Àåºñ´Â ¿¡¾îÄÁ, ³ÃÀå°í ¹× ³Ã°£ ÀúÀå°ú °°Àº ³Ãµ¿ ÀåºñÀÇ ¼³Ä¡, Å×½ºÆ® ¹× À¯Áö º¸¼ö¸¦À§ÇÑ º¸Á¶ ÀåºñÀÔ´Ï´Ù. ÀÌ Àåºñ´Â ÀÌÁß ¾Ð·Â Å×½ºÆ®, ÀÌÁß ¿Âµµ Å×½ºÆ® (¼·¾¾/Ⱦ¾), µðÁöÅÐ Æǵ¶, ´ÙÁß ´ÜÀ§ ¾Ð·Â º¯È¯, ´ÙÁß ¸ðµå ±â´É ¹× ³»Àå ³Ã¸Å µ¥ÀÌÅͺ£À̽º¸¦ °®Ãß°í ÀÖ½À´Ï´Ù. ¶ÇÇÑ °ú³Ã°¢ °ú¿À» °è»êÇÏ¿© ÀÛµ¿ °øÁ¤ µ¥ÀÌÅ͸¦ Á÷Á¢ ÀÐÀ» ¼ö ÀÖµµ·ÏÇÕ´Ï´Ù. ¶ÇÇÑ Áø°ø ÃøÁ¤ÀÇ ¹éºÐÀ²À» Å×½ºÆ®ÇÕ´Ï´Ù. ¾Ð·Â ´©Ãâ ÃøÁ¤, ´©Ã⠽𣠱â·Ï. ÀÌ Àåºñ´Â °í°µµ ¿£Áö´Ï¾î¸µ Çöó½ºÆ½°ú À¯¿¬ÇÑ ¹Ì²ô·³ ¹æÁö ½Ç¸®ÄÜ µðÀÚÀÎÀ» »ç¿ëÇÏ¿© Àüü ±â°è°¡ °ß°íÇÏ°í Æí¾ÈÇÏ°Ô ÀâÀ» ¼ö ÀÖ½À´Ï´Ù. ³»ÀåµÈ 32 ºñÆ® µðÁöÅРó¸® ÀåÄ¡ ¹× °íÁ¤¹Ð µ¥ÀÌÅÍ ¼öÁý ÀåÄ¡, ³ôÀº µ¥ÀÌÅÍ ¹× ¾ÈÁ¤¼º. ´ëÇü ¾×Á¤ µð½ºÇ÷¹ÀÌ, LCD ¹é¶óÀÌÆ® Áö¿ø, ¼±¸íÇÏ°í Àб⠽¬¿î µ¥ÀÌÅÍ µð½ºÇ÷¹ÀÌ, Æí¸®ÇÑ Á¶¸í ÀÛµ¿. ±ä ¼ö¸í ¹ëºê ½ºÀ§Ä¡, 1/4 ÀÎÄ¡ Ç¥ÁØ ÀÎÅÍÆäÀ̽º ¼³°è·Î ±â±âÀÇ ³»±¸¼º°ú ´Ù¾ç¼ºÀ» º¸ÀåÇÕ´Ï´Ù.
¹Ì±¹ NIST Ç¥ÁØ¿¡ µû¸¥ ³Ã¸Å ³»Àå 93 Á¾ NIST
¼³°è ¹× »ý»êÀ» À§ÇÑ EC/EN61010-1 ¾ÈÀü Ç¥ÁØ.
1. µðÁöÅÐ ¸Å´Ï Æúµå ¾Ð·Â Å×½ºÅÍ¿¡ ÀÇÇØ ÃøÁ¤ µÈ ¾Ð·ÂÀº °ÔÀÌÁö ¾Ð·ÂÀÔ´Ï´Ù. 2. ¾Ð·Â Å×½ºÆ® ¹üÀ§´Â-101Kpa ~ 6Mpa (-0.1bar ~ 60bar) ÀÔ´Ï´Ù. 3. ÇÑ°è ¾Ð·ÂÀº 10 Mpa (100 bar) ÀÔ´Ï´Ù. 4. Ç¥ÁØ È£½ºÀÇ ÃÖ´ë ÀÛµ¿ ¾Ð·ÂÀº 600 PSIÀÔ´Ï´Ù (´ë·«ÀûÀÎ 4.13 Mpa, 41.3 bar ). ÇÑ°è ¾Ð·ÂÀº 3000 PSI ±Ù»çÄ¡ 20.68 Mpa, 206.8 bar) ÀÔ´Ï´Ù. 5. Å×½ºÆ® Àü¿¡ Å×½ºÆ® ÀåºñÀÇ Á¤°Ý ¾Ð·Â °ªÀ» È®ÀÎÇϽʽÿÀ. ±â±âÀÇ ¹üÀ§¸¦ ÃÊ°úÇÏ¸é »ç¿ëÇÏÁö ¸¶½Ê½Ã¿À. Æ÷Àå µÈ È£½º°¡ ¾Ð·Â ¿ä±¸ »çÇ×°ú ÀÏÄ¡ÇÏÁö ¾ÊÀ¸¸é Å×½ºÆ®¸¦ À§ÇØ ÀûÀýÇÑ ±³Ã¼Ç°À» »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
Á¦Ç° »ç¾ç:
¾Ð·Â Å×½ºÆ®: °ÔÀÌÁö ¾Ð·Â ¾Ð·Â Å×½ºÆ® ÀåÄ¡: Kpa; Mpa; bar; inHg; PSI. ¾Ð·Â Å×½ºÆ® ¹üÀ§: 0 Kpa - 6000 Kpa ¾Ð·Â Å×½ºÆ® ÇØ»óµµ: 1 Kpa ¾Ð·Â Å×½ºÆ® Á¤È®µµ: +/- 0.5%(FS)+ 5dgt ¾Ð·Â °úºÎÇÏ ÇÑ°è: 10000 Kpa (10 Mpa; 100 bar;) Áø°ø Å×½ºÆ®: »ó´ë Áø°ø Áø°ø Å×½ºÆ® ÀåÄ¡: Kpa; Mpa; bar; inHg; PSI. Áø°ø Å×½ºÆ® ¹üÀ§: -101 Kpa - 0 Kpa Áø°ø Å×½ºÆ® ÇØ»óµµ: 1 Kpa ¿Âµµ Å×½ºÆ® À¯´Ö: °C (¼·¾¾), °F (Ⱦ¾) ¿Âµµ Å×½ºÆ® ¹üÀ§: -40 °C-150 °C (-40 °F-302 °F) ¿Âµµ Å×½ºÆ® ÇØ»óµµ: 0.1 °C (-40 °C-99.9 °C), 1 °C (100 °C-150 °C) 0.1 °F (-40 °F-99.9 °F), 1 °F (100 °F-302 °F) ¿Âµµ Å×½ºÆ® Á¤È®µµ: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt ³»ÀåÇü 93 Á¾·ùÀÇ ³Ã¸Å NIST: ¹Ì±¹ NIST Ç¥ÁØ¿¡ µû¸£¸é Àü¿ø °ø±Þ ÀåÄ¡: 4X1.5V (SIZE.AA / LR6) ¹èÅ͸®´Â Æ÷ÇԵǾî ÀÖÁö ¾Ê½À´Ï´Ù! Å©±â: 170*110*50mm ¹«°Ô: 950g
Âü°í »çÇ×:
1. ¸ð´ÏÅÍ ¹× Á¶¸í È¿°ú°¡ ´Ù¸£±â ¶§¹®¿¡ Ç׸ñÀÇ ½ÇÁ¦ »ö»óÀÌ ±×¸²¿¡ Ç¥½ÃµÈ »ö»ó°ú ¾à°£ ´Ù¸¦ ¼ö ÀÖ½À´Ï´Ù. °¨»çÇÕ´Ï´Ù! 2. ¼öµ¿ ÃøÁ¤À¸·Î ÀÎÇÑ ¾à°£ÀÇ ÃøÁ¤ ÆíÂ÷¸¦ Çã¿ëÇϽʽÿÀ.
Æ÷Àå ¸ñ·Ï
1x ³Ãµ¿ µðÁöÅÐ ¸Å´ÏÆúµå °ÔÀÌÁö 1x »ç¿ëÀÚ ¼³¸í¼ (¿µ¹®) ¹èÅ͸®°¡ Æ÷ÇÔµÇÁö ¾ÊÀ½
|
|
|
|
|