1. Performance characteristics:
PH-110 industrial ph meter, pH meter intelligent industrial upgrading products, the pH of the sewage continuous measurement and control, this device is suitable for urban sewage treatment plants, chemical industry, printing and dyeing, paper, pharmaceutical, electroplating and environmental protection fields.
Combined depending on the environment and the characteristics of the water supply industry, international standards, taking into account the special circumstances of the electrical design specifications, adding 220V AC and safe low voltage 24V AC, 24V DC power supply options.
The main features of this product:
Chinese factory standard configuration interface, the language of the menu, you can toggle Britain
available for pH / ORP measurement, upper and lower control, current output, digital communications
can be set to automatic temperature compensation or manual compensation
pH high alarm, low limit alarm dual relay, hysteresis can be adjusted freely
meter transmission port isolation mode, maximum loop resistance is greater than 300¥Ø
voice alarm can switch function, through the interface option is set on or off
selectable LCD backlight power saving mode, the timer automatically turns off
high-performance CPU, good electromagnetic compatibility
password management function to prevent the misuse of non-professionals
2. The main technical indicators:
Measuring range: pH (0 - 14 pH); ORP (-1900 - +1900 mV)
Accuracy: + 0.02 pH; + 1 mV
Resolution: 0.01pH; 1mV
Stability: ¡Â 0.02 pH / 24 ; ¡Â 3 mV / 24
pH standard solution: 4.00 / 6.86 / 9.18
Display: 128 * 64 dot matrix LCD
Temperature compensation: 0-100 ¡Émanual / automatic (NTC10K)
Signal output: 4-20mA output isolation protection maximum loop resistance 300¥Ø
Alarm output: low limit alarm contacts of a group (3A / 250 V AC), normally open contact relay
Power supply: AC 220V ¡¾10% 50Hz
Power consumption: ¡Â3W
Environmental conditions: (1) Temperature 0 ~ 60 ¡É (2) humidity ¡Â85% RH
Dimensions: 96 ¡¿ 96 ¡¿ 110mm (height ¡¿ width ¡¿ depth)
Hole Size: 92 ¡¿ 92mm (height ¡¿ width)
3. Fixed bracket
The controller from the front into the panel, and then loaded up and down the two retaining clips lock can be fixed with a screwdriver.
![](https://ae01.alicdn.com/kf/S3a26d39fe3494c8498c313677186a5b2X.jpg?width=241&height=248&hash=489)
Fixed bracket Figure
4. After the dial connection location map:
![](https://ae01.alicdn.com/kf/Se573732a9e86416c98522af38c53c248m.jpg?width=263&height=230&hash=493)
After the dial Figure
5. wiring instructions:
1. TEMP1: Warming Interface
2. TEMP2: Warming Interface
3. REF: reference electrode (black) Interface
4. INPUT: measuring electrode (red) Interface
5. A: 485 Communication Interface
6. B: 485 Communication Interface
7. mA +: 4 ~ 20mA output terminal +
8. mA-: 4 ~ 20mA output terminal -
9. LO: low alarm normally open contact 1
10. LO: low alarm normally open contact 2
11. HI: high alarm normally open contact 1
12. HI: high alarm normally open contact 2
13. NC: Undefined
14. NC: Undefined
Fifteen. N: 220V Power Interface
16. L: 220V Power Interface
6. Measure the electrode mounting
Installation methods and precautions
![](https://ae01.alicdn.com/kf/S79a58d0a0c544c6a8f99eb17e288fed8X.jpg?width=429&height=273&hash=702)
Figure 3 (common several installation methods)
In order to ensure the correct electrode in the pipeline measured pH value, should be avoided between the measuring cell and cause bubbles inaccurate data, please press the map stringent installation:
![](https://ae01.alicdn.com/kf/S041910c3e97e4679b6b28f027e3e87a2h.jpg?width=500&height=157&hash=657)
Note: (1) the electrode should be installed in the bypass of the main line, the front end valve should be installed to control the flow rate, the flow should be as small as possible, generally as long as the outlet have a stable solution to drip out. Electrode should be mounted vertically and deep into the activities of water, the outlet than the inlet should be high in order to ensure the electrodes were immersed in the solution.
(2) the electrode should be calibrated before installation.
(3) measuring signal belongs to weak electrical signals, which cable should be independent of trace collection, Suppress and power lines, control lines are connected to the same set of cable connectors or terminal blocks in order to avoid interference or breakdown measurement unit.
(4) measurement cables are too short, please contact the manufacturer or supplier before the convention (generally less than 10m).
2, the electrode signal lines extend and shorten precautions:
Since the purchase of non-trial extension cable electrode wire
Cable structure anatomy (without warming):
[1] outside the electrode sheath (black) [2] electrode wire network cable (R E F)
![](https://ae01.alicdn.com/kf/Seb1147d1d5644f528911f2fcd2c28a24y.jpg?width=303&height=92&hash=395)
[3] black conductive rubber (black) [4] white protective tube (white) [5] centerline (INPUT)
Note: The site appeared as the electrode signal line is too long need to cut, cut must be pulled out after the 3rd conductive rubber Phi. No person could easily lead to the 5th line and the 2nd electrode measuring electrode reference line short, can not be measured! ! ! The need to extend the vendor, please contact! ! !
7. Feature Sets:
7.1 Screen button keyboard Features:
7.2 main interface:
![](https://ae01.alicdn.com/kf/Sb187b477ba1e4cafa582873bc91f5e9eD.jpg?width=554&height=135&hash=689)
NOTE: The main interface through the "ESC" you can switch to the browser interface, without having to enter the "Menu" interface can browse set parameters.
7.3 browser interface display:
![](https://ae01.alicdn.com/kf/S3fd32987a35740babf869f97c3e01c7co.jpg?width=554&height=163&hash=717)
NOTE: The browser interface via the "up key" to view the parameter status poll by "ESC" to switch back to the main screen.
7.4 Main Menu interface display:
![](https://ae01.alicdn.com/kf/Sf054942913604a86a3c2d8dd90ec839eR.jpg?width=246&height=267&hash=513)
In the main display screen, press the "OK" button to enter the user login screen, enter the password (0000) into the "Setup Menu" interface that`s menu described in the following table
NO
|
Menu Name
|
Menu Introduction
|
1
|
Measurement parameters
|
Can be electrode type PH / ORP conversion, warming mode is set; if manually input temperature value measured solution
|
2
|
Control parameters
|
Set the pH or ORP overrun overrun control
|
3
|
Transmission parameters
|
Set the pH and ORP transmitter starting amount range migration
|
4
|
Password Change
|
Reset Password
|
5
|
Communication Settings
|
Set the baud rate and the instrument address
|
6
|
Backlight settings
|
Setting the backlight normally open or delay off
|
7
|
Voice alarm
|
Setting the buzzer on or off
|
8
|
Factory parameters
|
To restore the instrument parameters to the parameter status before leaving the factory
|
9
|
Electrode correction
|
This menu is only open when the pH electrode type selected
|
7.5 interface measurement parameters:
![](https://ae01.alicdn.com/kf/S5eb46367d7b7464d82113761c23e875fz.jpg?width=248&height=115&hash=363)
Note: By pressing the "up" can choose to enter "electrode types" or "temperature compensation" parameter setting, press "OK" to enter.
7.6 Control parameters interface:
![](https://ae01.alicdn.com/kf/Sbdab78f6ea544b608c3d1bd29f26c799E.jpg?width=247&height=123&hash=370)
Note: By pressing the "up" can choose to enter "high reported Settings" or "under-reporting settings" parameter setting, press "OK" to enter after setting the alarm values.
7.7 transmission interface parameters
![](https://ae01.alicdn.com/kf/S6424fe7f50d44a539759d09b571d8ed6f.jpg?width=243&height=96&hash=339)
NOTE: by pressing the "Right" and "Up" input parameter, press "OK" to save.
7.8 Password Change interface:
Note: First enter the old password, if entered correctly, you can enter into the "New Password" screen, press "OK" to save the password change.
7.9 backlight setting interface:
Note: First select the backlight "delay off" or "Hold On", if you select the "delay off" will have to enter the "delay time."
7.10 Alarm voice interface:
Note: When you select an alarm sound "ON" or "OFF", press "OK" to save the selection.
7.11 pH electrode calibration interface:
Note: This section operation, see "Instrument calibration" section.
7.12 factory default settings:
Menu Name
|
Setting range
|
Factory Defaults
|
Electrode Type
|
PH electrode / ORP electrode / antimony electrode
|
PH electrode
|
Temperature compensation
|
Automatic / manual
|
Manually
|
Manually Warming value
|
0 ~ 100 ¡É
|
25 ¡É
|
Pull-high newspaper
|
pH: 1.00 ~ 14.00pH
|
pH: 12.00 pH
|
|
ORP:+ 10 ~ + 1999mV
|
ORP:+ 1900 mV
|
Disconnect the high reported values
|
pH: 0.00 ~ 13.99pH
|
pH: 11.00 pH
|
(Less than pull value)
|
ORP: 0 ~ + 1998mV
|
ORP:+ 1800 mV
|
Pull-low alarm
|
pH: 0.00 ~ 13.00pH
|
pH: 2.00 pH
|
|
ORP:- 1999 ~ - 10mV
|
ORP:- 1800 mV
|
Underreporting off value
|
pH: 0.01 ~ 14.00pH
|
pH: 3.00 pH
|
(Greater than pull value)
|
ORP: - 1998 ~ 0mV
|
ORP:- 1900 mV
|
4mA corresponding value
|
pH: 0.00 ~ 13.00pH
|
pH: 0.00 pH
|
|
ORP:- 1999 ~ 0mV
|
ORP:- 1999 mV
|
20mA corresponding value
|
pH: 0.01 ~ 14.00pH
|
pH: 14.00 pH
|
(Greater than 4mA value)
|
ORP: 0 ~ +1999mV
|
ORP:+1999 mV
|
user password
|
0 ~ 9999
|
1000
|
Baud Rate
|
2400,4800,9600
|
4800
|
Native address
|
2 ~ 99
|
2
|
Backlight settings
|
Always / Delay
|
Delay
|
Delay time
|
5 ~ 99 S
|
60 S
|
Voice alarm
|
Open / Close
|
Open
|
8. The alarm relay (control dosing) Setting
8.1 If you add acid to adjust lye, such as requiring the addition of acid PH value of more than nine, to adjust to after 6 stops, should first dosing pump power the zero line cut, and then the two thread connected to a high point after the meter dial namely " HI "two terminals, then set the high point of the relay:
Press the "OK" button, enter your password into the "Setup Menu" screen, select "Control Parameters" Press "OK" button, then select "Set high alarm" will pull high value is set to 9, the high point off value set to 6, press "OK" button. You can now achieve more than 9 PH value added acid, adjusted to stop after six.
8.2 If alkali regulate acid, such as requiring PH value of less than 6 alkali, adjusted to stop after 9, two thread should first dosing pump power cut after the zero line connected to the meter dial lows namely " LO "two terminals, then set low relay:
Press the "OK" button, enter your password into the "Setup Menu" screen, select "Control Parameters" Press "OK" and then choose "underreporting Settings" will pull low value is set to 6, the low value is set to OFF 9. Press "OK" button. It can now achieve PH value of less than 6 adding alkali to adjust to after 9 stops.
Note:
Relay drive inductive load, please install the intermediate relay, to avoid being back EMF when the contact breaking inductance breakdown ionization, burning the contacts.
9. Maintenance:
Section 9.1 PH
9.1.1 Instrument maintenance:
(1) The instrument input (measuring electrode sockets) must be kept dry and clean to prevent dust and moisture intrusion.
(2) should avoid long electrode immersed in a protein solution and acid fluoride solution, avoid contact with the silicone oil.
(3) after long-term use of the electrode, such as found in slope slightly lower, the lower end of the electrode can be immersed in 4% HF solution (hydrofluoric acid) for 3 to 5 seconds, and then washed with distilled water, then 0.1mol / L hydrochloric acid immersion the electrode Fuxin.
(4) In order to more accurately measure shall be regularly calibrated electrodes and washed with distilled water.
(5) The instrument should be placed in a dry environment or control box, to avoid water droplets caused by sputtering or moisture meter drain or measurement error.
9.1.2 Instrument Calibration:
9.1.2 correction before work, check the instrument wiring is correct, the Power warm up for 30 minutes.
9.1.3 with a good 4.00pH, 6.86pH, 9.18pH three standard solution.
Method: use distilled water, distilled water twice distilled better, cut the plastic bag in the reagent into the beaker, with the amount of deionized water to dissolve and wash bags, then pour 250ml volumetric flask, dilute to the mark fully shake well, pour sample bottle label use.
9.1.4 The electrode rinse with distilled water and a clean and dry with filter paper, and then the electrode into a standard buffer 4.00pH gently stirring several times, the screen displays "4.00pH Calibration", the central display mV output voltage value of the electrode. Wait at least one minute, until mV after stabilization press "Enter OK" is calibrated, 4.00 will be prompted after the completion of a successful calibration.
9.1.5 Repeat the above two steps, namely calibration 6.86pH, 9.18pH and two points. After each label a standard solution, the electrode must use distilled water to clean and dry with filter paper before they can be put under a standard standard liquid inside.
9.1.6 above calibration is completed automatically goes into solution temperature calibration interface, and if automatic temperature compensation, display solution temperature measuring electrode, if manual temperature compensation, you can enter the solution temperature using the keys, press the "Enter OK" to save the parameter that is complete calibration,
NOTE: If you do not strictly follow the above steps, at any step press "Exit ESC" to exit to the main screen, in front of the calibration parameters are not saved.
PH standard buffer solution standard values
Temperature ¡É
|
0.05mol/kg
|
0.025mol/kg
|
0.01mol/kg
|
PotassiuM biphthalate
|
Phosphate mixture
|
sodium tetraborate
|
5
|
4
|
6.95
|
9.39
|
10
|
4
|
6.92
|
9.33
|
15
|
4
|
6.9
|
9.28
|
20
|
4
|
6.88
|
9.23
|
25
|
4
|
6.86
|
9.18
|
30
|
4.01
|
6.85
|
9.14
|
35
|
4.02
|
6.84
|
9.11
|
40
|
4.03
|
6.84
|
9.07
|
45
|
4.04
|
6.84
|
9.04
|
50
|
4.06
|
6.83
|
9.03
|
55
|
4.07
|
6.83
|
8.99
|
60
|
4.09
|
6.84
|
8.97
|
9.2 ORP part
9.2.1 ORP standard solution preparation methods:
(1) 86mV: Standard 7.00pH buffer solution was added a slight excess quinhydrone.
(2) 256 mV: Standard 4.00pH buffer solution was added a slight excess quinhydrone.
(3) standard solution to save time is 3 days
9.2.2 ORP electrode detection:
(1) ORP electrodes do not like PH electrodes require calibration standard solution, but it must mV standard solution to check ORP electrodes, the most important aim is to see whether the effective electrode.
(2) the electrode clean with water and wipe with a soft towel.
(3) the electrode into standard solution prepared mV until the display is stable.
(4) to see whether the display mV value is close to the standard solution, if the error is within plus or minus 35mV, the electrode can be used normally, or we need to change the electrode
10.4-20mA current output is calculated
10.1 PH current output is calculated:
10.1.1 machine factory output current is defined as: 0 pH of 4 mA corresponding value; 14 pH to 20 mA corresponding value
10.1.2 I = (D - 4 mA corresponding value) ¡¿ (16 / (20 mA corresponds to the value - 4 mA corresponds to the value)) + 4.00
10.1.3 I = (D - 0) ¡¿ (16/14) + 4.00
10.1.4 Note: I is the output current value, 4 mA¡ÂI¡Â20 mA
10.1.5 D for the instrument display pH value, 0.00pH¡ÂD¡Â14.00pH
. 10.2 ORP current output is calculated:
10.2.1 machine factory output current is defined as: -2000mV to 4 mA corresponding value; + 2000mV to 20 mA corresponding value
10.2.2 I = (D - 4 mA corresponding value) ¡¿ (16 / (20 mA corresponds to the value - 4 mA corresponds to the value)) + 4.00
10.2.3 I = (D - (-2000)) ¡¿ (16 / (+2000 - (-2000))) + 4.00
10.2.4 I = (D + 2000) ¡¿ (16/4000)) + 4.00
10.2.5 Note: I is the output current value, 4 mA¡ÂI¡Â20 mA
10.2.6 D for the instrument display ORP value, -2000mV¡ÂD¡Â + 2000mV
11. The fault diagnosis and troubleshooting:
11.1 No display controller?
A: No power or blown fuse. Check the power supply line and fuse.
11.2 display numbers but on the next bounce?
A: The electrode wire or electrode moist ceramic contamination. Check the electrode lines, cleaning ceramic hole (0.1 m HCL)
11.3 standard solution pH4.01 and pH6.86 not adjust?
A: The external electrode contamination, the electrode wire damp, damaged or cracked electrode, an electrode ceramic blocked. Rinse the electrode (O.1 m HCL), check the electrode wire, replace the electrode, cleaning ceramic hole (0.1 m HCL).
11.4 Digital slow response?
A: The electrode film or ceramic hole contamination. Cleaning entire electrode.
11.5 When the actual PH value has changed a lot and control the display value has changed very little?
A: The ceramic electrode clogging electrode aging, slow response. Rinse the electrode (0.1 m HCL), with regeneration solution.
11.6 Controller Display figures do not move?
A: electrode breakage, electrode cable short-circuited. Replace the electrode, check the cable.
11.7 The controller does not operate within the relay or after dosing solution PH value change?
A: The relay is damaged, the controller set incorrectly liquid enough. Contact the vendor to replace the relay, change the setting value, add liquid.
12. Complete sets of equipment:
Electric meter, one Taiwan, one electrode, a manual, a set of standard solution
Company Information
Hangzhou Qi Wei Instrument Co., Ltd. set the development, production, sales, service as one of professional high-tech enterprise, the company`s current development of a number of series of electrochemical analysis instruments, whiteness detection equipment, UV analytical instruments, machinery and electronic products, a few dozens of product. Market reputation of the "General Instrument family reputation" Product design novel, the atmosphere, fine workmanship. Reliable quality and stable performance. The company will be "pioneering, innovation, integrity and cooperation" for the purpose, with the majority of customers and friends go hand in hand, and common development.
Profile
Desktop / Portable / pen type pH meter, PH meter industry in red type, desktop / portable conductivity meter, sodium ion meter, a fluorine ion meter, a chlorine ion meter, ORP meter, desktop / portable turbidity meter, desktop / portable chroma instrument, beer colorimeter, chlorine detector, desktop / portable whiteness meter, with three ultraviolet analyzer, portable ultraviolet analyzer, black-box type ultraviolet analyzer, colony counter, digital mixer, high-speed disperser homogenizer, High-speed dispersion mill, disc sampler, infrared oven and other merchandise.
Business purpose
Quality first, service first; innovation, integrity and cooperation.